MIL-L-87177A
TABLE IV. Grade A typical formulation.
Parts |
Component Description |
|
by |
(Formula) |
|
Weight ( |
Proprietary Name or Trade Name) |
Supplier |
96.61 |
Freon TF |
E.I. DuPont De Nemours and Company (Inc) Wilmington DE 19898 |
2.36 |
Selig 1121 (A proprietary mixture registered with Environmental Health and Safety Department) |
Selig Chemical Industries Atlanta GA 30336 |
1.03 |
Poly Alpha Olefin |
Gulf Oil Corporation |
(6 centist |
okes at 99°C [210°F]) |
Pittsburgh PA 15219 |
NOTE: Grade B has proprietary corrosion inhibiting compound added.
6.5 Heat testing of metal containers. Section 173.306 of the Department of Transportation Regulations specifies that each completed metal container filled for shipment must be heated until the contents reaches a minimum temperature of 130oF without evidence of leakage, distortion, or other defects.
6.6 Subject term (key word) listing
Synthetic sea water
Gas pressurized containers
Compound
6.7 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extensiveness of the changes.
Custodians: Preparing activity: Army - CR Air Force - 11
Navy - AS (Project No. 9150-1033)
Air Force - ll
Review activities: Air Force - 68
User Activities: Army - AR Navy - EC