MIL-L-87177A
TABLE I. Physical and chemical properties.
Characteristics Limits
Dryness 0.0100 gram (max)
Flash point 243°C(470°F)(min)
Grade A Synthetic No visible corrosion.
sea water Fine localized pitting shall displacement not be cause for rejection
Dielectric breakdown 25,000 volts (min)
Lubricity 1.20 mm wear scar diameter
(max)
Residue soluble No visible residue trichlorotrifluoroethane
Oxidation stability Less than 5 pounds per 100 hours
Grade A corrosivity No visible pitting, etching, or dark discoloration. No weight change (milligrams/ cm2) greater than 0.5 for magnesium, cadmium and zinc; nor greater than 0.2 for aluminum, copper and brass.
Grade B corrosion No evidence of corrosion on the resistance base metal when exposed for 168 hours in accordance with methods specified in section 4.
Sprayability Sprayable.
Grade C shall meet all the physical and chemical properties in table I except the corrosivity (Grade A) and corrosion resistance (Grade B) requirements.
4. QUALITY ASSURANCE PROVISIONS
4.1.1 Responsibility for compliance. All items shall meet all requirements of sections 3 and 5. The inspection set forth in this specification shall become a part of the contractor's overall inspection system or quality program. The absence of any inspection requirements in the specification shall not relieve the contractor of the responsibility of ensuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract. Sampling inspections, as part of manufacturing operations, is an acceptance practice to ascertain conformance to
requirements, however, this does not authorize submission of known defective material,
5
Source: https://assist.dla.mil -- Downloaded:
Check the source to verify that this is the current version before use.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business