MIL-L-87177A
under the atmospheric conditions of 4.3.1 in a draft-, dust- and fume- free atmosphere.
4.3.3 Inspection lot. An inspection lot shall consist of all material produced during a single batch operation and offered for acceptance at one time.
4.4 First article inspection
4.4.1 Waiver of article sample inspection. If a contractor has previously furnished the compound in accordance with the requirements of this specification and his product has been found to be satisfactory, the requirement for a first article sample and its submittal for any subsequent contract or order may be waived at the discretion of the procuring activity.
4.4.2 First article samples. First article sample shall consist of at least five type I filled pressurized containers (see 3.3.1), or 5 quarts of the type II compound (see 3.3.2). Samples shall be selected at random from materials (see 3.1) which have been manufactured or used for filling the contract.
4.4.2.1 Identification of samples. Samples shall be plainly identified by securely attached durable tags marked with the following information:
LUBRICANT, CORROSION PREVENTIVE COMPOUND, WATER DISPLACING, SYNTHETIC GRADE
Samples of material subjected to first article
Name of Manufacturer (Plant in which material is manufactured) Manufacturer's Designation
Date of Manufacture
Submitted by (Name) (Date) for Contract No.
The manufacturer shall submit a copy of test results with the samples showing conformance with all the requirements of this specification and the applicable requirements of regulation 49 CFR 173.300 of the Department of Transportation. The manufacturer shall submit a certified statement specifically identifying each ingredient in the compound by chemical name, source and percentage by weight.
4.4.3 First article tests. First article sample(s) shall be subjected to all the tests specified in table II to determine compliance with the requirements of section 3 herein.
4.5 Quality conformance inspection. Samples shall be labeled completely with information identifying the purpose of the sample, name of product, specification number, lot and batch number, date of sampling and contract number.
4.5.1 Sampling plan A. One type I filled pressurized container (see 3.3.1) and one quart of the type II compound (see 3.3.2) shall be selected in accordance with
MIL-STD-105, inspection level S-3 with an AQL 4.0 percent defective and shall be
subjected to the tests specified in table III.