MIL-DTL-85694A
TABLE II. List of elements and formulations by type.
Element (chemical symbol)
Spectrometric Oil Standards Types
D19-0
D21-XXX D19-XXX D12-XXX
D3-100
Aluminum (Al)
<1 ppm
1.00 X
1.00 X
1.00 X
Chromium (Cr)
<1 ppm
1.00 X
1.00 X
1.00 X
Copper (Cu)
<1 ppm
1.00 X
1.00 X
1.00 X
Iron (Fe)
<1 ppm
1.00 X
1.00 X
1.00 X
Lead (Pb)
<1 ppm
1.00 X
1.00 X
1.00 X
Magnesium (Mg)
<1 ppm
1.00 X
1.00 X
1.00 X
Nickel (Ni)
<1 ppm
1.00 X
1.00 X
1.00 X
Silicon (Si)
<1 ppm
1.00 X
1.00 X
1.00 X
Silver (Ag)
<1 ppm
1.00 X
1.00 X
1.00 X
Sodium (Na)
<1 ppm
1.00 X
1.00 X
1.00 X
Tin (Sn)
<1 ppm
1.00 X
1.00 X
1.00 X
Titanium (Ti)
<1 ppm
1.00 X
1.00 X
0.92 X
Boron (B)
<1 ppm
1.00 X
1.00 X
1.15 X
Molybdenum (Mo)
<1 ppm
1.00 X
1.00 X
0.85 X
Zinc (Zn)
<1 ppm
1.00 X
1.00 X
1.00 X
Barium (Ba)
<1 ppm
1.00 X
1.00 X
Cadmium (Cd)
<1 ppm
1.00 X
1.00 X
Manganese (Mn)
<1 ppm
1.00 X
1.00 X
Vanadium (V)
<1 ppm
1.00 X
1.00 X
Calcium (Ca)
<1 ppm
1.00 X
Phosphorus (P)
<1 ppm
1.00 X
Where X = nominal concentration of spectrometric oil standard in ppm
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified
as follows:
a. Qualification inspection (see 4.2).
b. Conformance inspection (see 4.3).
4.2 Qualification inspection. Qualification inspection shall consist of testing to all the tests
specified in Table I and 4.4 through 4.4.3. The extended storage stability test (see 4.4.3) shall be
performed after the candidate product has passed all other qualification tests. Tentative
qualification approval may be granted to products undergoing the extended storage stability tests.
Upon successful completion of the extended storage stability test, full qualification approval may
be granted. Failure to pass the extended storage stability test is cause for withdrawal of
qualification approval.