VV-G-671G
3.4 Workmanship. The grease shall be homogeneous, smooth in texture, free of entrapped air, and shall have no odor of rancidity, perfume, or free alcohol.
4. QUALTIY ASSURANCE PROVISIONS
4.1 Reserved.
4.2 Lot.
4.2.1 Lot formation. A lot shall consist of all the grease produced by one manufacturer, at one plant, from the same materials and under essentially the same conditions, provided the operation is continuous and does not exceed a 24 hour period. In the event the process is a batch operation, each batch shall constitute a lot (see 4.2.1.1).
4.2.1.1 Batch. A batch is defined as that quantity of material which has been manufactured by a unit chemical process and subjected to a physical mixing operation intended to make the final product substantially uniform.
4.3 Sampling.
4.3.1 Sampling for the examination of filled containers. A random sampling of filled unit containers shall be taken from each lot in accordance with ANSI/ASQ Z1.4.
4.3.2 Sampling for tests. The sample for tests shall consist of two 2.27 kilogram (kg) samples of grease taken at random from filled containers from each lot of grease. For users who obtain grease in large containers, two 2.27 kg samples shall be taken in accordance with
ASTM D 4057. The lot shall be unacceptable if either sample fails to comply with any of the tests specified in 4.5.
4.4 Inspection. The grease shall be examined for conformance with 3.4 in addition, the manufacturer shall provide certification of non-carcinogenicity as specified in 3.2.1 (i.e., materials are not considered carcinogenic or potentially carcinogenic).
4.4.1 Classification of inspection. The inspection requirements are classified as follows:
a. Quality conformance inspection (see 4.5).
b. Inspection of preparation for delivery (see 4.6).
4.4.2 Inspection conditions. Unless otherwise specified, all tests shall be conducted on unworked grease. The physical limits specified in table II shall apply to the average of determinations made on the sample.
4.4.3 Examination of filled containers. Samples taken in accordance with 4.3.1 shall be examined for compliance with MIL-STD-290 with regard to fill, closure, sealing and leakage requirements. Any container having one or more defects or under the required fill shall be rejected. If the number of defective or under filled containers exceeds the acceptance number for
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business