MIL-PRF-6083G
TABLE III. Sampling for particle size contamination.
Container size
Sample size, mL
Determinations per sample
1 pint (pt) (0.473 liters (L))
100
1
1 quart (qt) (0.946 L)
100
1
1 gallon (gal) (3.785 L)
200
2
5 gal (18.9 L)
300
3
55 gal (208.2 L)
600
6
4.4.3 Examination of filled containers. Filled containers shall be examined with regard to fill,
closure, sealing, and leakage. Any container having one or more defects or under the required fill shall be
rejected.
4.5 Methods of inspection and test. Qualification inspection shall consist of the tests for all of
the requirements specified in Section 3 and Table I. Tests shall be in accordance with Table I and with
4.5.1 through 4.5.2 as applicable. Unless otherwise specified (see 6.2), reagent water conforming to the
requirements for type III of ASTM D1193 and reagent-grade chemicals shall be used in all tests. Blank
determinations shall be run and corrections applied when necessary.
4.5.1 Compatibility. Samples of the candidate hydraulic fluid in amounts of 20mL, 100mL, and
180mL shall be mixed with samples from each of the fluids previously qualified under this specification.
Total volume of each mixture shall be 200mL. Mixtures shall be prepared in 250mL flasks with stoppers.
The flasks shall be thoroughly agitated and then stored in an oven at 135C for 3 hours. At the end of this
time, none of the mixtures shall show any sign of sediment, turbidity, or crystallization. The samples
shall then be stored at -54C for a period of 3 hours. Slight turbidity after this time, which later
disappears, will be permitted in the samples. Compatibility tests described herein shall also be conducted
with representative fluids qualified to MIL-PRF-5606, MIL-PRF-46170, MIL-PRF-83282, and MIL-
PRF-87527.
4.5.2 Shear stability.
4.5.2.1 Calibration of the instrument shall be conducted in accordance with ASTM
D2603 using ASTM Reference Fluid B. Repeat, as needed, to determine the proper power
settings to produce a viscosity change of 15.0% at 40C. The viscosity shall be measured in
accordance with ASTM D445.
4.5.2.2 After successful calibration of the instrument, the control fluid (ASTM
Reference Fluid B) and test fluid shall be analyzed on the same day. The fluids shall be tested at
0C for 30 minutes.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD personnel,
these personnel need to contact the responsible packaging activity to ascertain requisite packaging