MIL-PRF-46010H
TABLE I. Test fluids.
Test Fluid
Specification
Anti-Icing Fluid
SAE AMS1424
Cleaning Compound, Solvent for Bore of Small Arms and Automatic
MIL-PRF-372
Weapons
Reagent Water
ASTM D1193, Type III
Substitute Ocean Water
ASTM D1141
Hydraulic Fluid, Rust Inhibited, Fire Resistant, Synthetic
MIL-PRF-46170
Hydrocarbon Base
Turbine Fuel, Aviation, Kerosene Types
MIL-DTL-83133, JP-8
Lubricating Oil, Aircraft Turbine Engine, Synthetic Base
MIL-PRF-23699
Lubricating Oil, Weapons, Low Temperature
MIL-PRF-14107
Lubricant, Cleaner and Preservative for Weapons and Weapon
MIL-PRF-63460
Systems
Damping Fluid, Silicone Base (Dimethylpolysiloxane)
VV-D-1078
3.9 Aluminum corrosion resistance. When subjected to heat and high humidity
conditions as specified in 4.5 on anodized aluminum panels, the bonded solid film lubricant shall
not show or cause discoloration, pitting, formation of white deposits, or other evidence of
corrosion.
3.10 Sulfurous acid - salt spray. When applied to steel panels and exposed to sulfurous
acid - salt spray in accordance with 4.5, there shall be no resultant pitting, visible corrosion, or
staining.
3.11 Salt - spray (fog) test. After being applied to steel panels, the lubricant shall show
not more than three rust spots per panel. Any spots shall be not greater than 1.0 mm in diameter,
after 100 hours exposure to a 5% salt spray solution in a salt fog cabinet in accordance with 4.5.
3.12 Solids content. The lubricant shall contain not less than 40 percent by weight of
solid material when tested in accordance with 4.5.2.
3.13 Storage stability. The fluid lubricant, after a minimum storage period as specified
in 4.5.3, shall conform to the requirements for endurance life, (see 3.7), the sulfurous acid - salt
spray, (see 3.10) and the salt-spray (fog) test (see 3.11) when tested in accordance with 4.5.
3.14 Volatile Organic Content. The lubricant shall contain not more than 250 g/L of
volatile organic content when tested as specified in 4.5.
3.15 Toxicity. The lubricant shall have no adverse effects on human health when it is
used as intended (see 6.1). Questions on toxicology shall be referred by the procuring activity to
the appropriate departmental medical service after consulting the qualifying activity (see 6.3).
6