4.6.2 Viscosity, kinematic. To determine conformance to 3.5.1, the oil shall be tested in
accordance with (IAW) ASTM D445, and exhibit a kinematic viscosity within the range specified
in Table II.
4.6.3 Pour point. To determine conformance to 3.5.2, the oil shall be tested IAW ASTM
D97, and shall exhibit a maximum pour point of 6° C.
4.6.4 Evaporation loss. To determine conformance to 3.5.3, the oil shall be tested at
100° C IAW ASTM D972, and shall exhibit a maximum mass percent evaporation loss of 5%.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified
in the contract or order (see 6.2). When actual packaging of material is to be performed by DoD
personnel, these personnel need to contact the responsible packaging activity to ascertain requisite
packaging requirements. Packaging requirements are maintained by the Inventory Control
Point's packaging activity within the Military Department or Defense Agency, or within the
Military Department's System Command. Packaging data retrieval is available from the managing
Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by
contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is
not mandatory.)
6.1 Intended use. Oil covered by this specification is intended for the preservation of
ferrous and non-ferrous metals and as a general purpose and ordinance lubricant where light
loads are anticipated. This oil is not intended for the protection of interior surfaces of internal
combustion engines.
6.2 Acquisition requirements. Acquisition documents will specify the following:
a.
Title, number, and date of this specification, and its related QPL (see 6.3.1).
b.
Title, number, and date of all documents referenced (see 2.1).
c.
Quantity of oil required (for bulk deliveries, specify the quantity in U.S. gallons).
d.
Type and size of container (see 1.3).
e.
Conformance tests required (contact activity listed in 6.3).
f.
Packaging requirements (see 3.3.2.1 and 4.3.2.1 and 5.1).
g.
Toxicological Data Requirements (see 3.3.2 and 4.3.2 and 6.4).