MIL-PRF-12070E
Table III. Chemical and physical tests.
Test
ASTM Method
Flash point, °C
D 92
Viscosity kinematic
D 445
At 100 °C minimum
maximum
Neutralization number , maximum
D 974
Pour point, °C
D 97
Ramsbottom carbon, % wt. maximum
D 524
Water and Sediment, % vol. maximum
D 1796
4.4 Sampling.
4.4.1 Sampling for the examination of filled containers. A random sample shall be taken from
each lot (see 6.3).
4.5 Test methods. Perform tests in accordance with table III.
4.5.1 Appearance. Visually examine the specimen for water, sediment, suspended particles,
grit and other foreign matter. The sample shall be clear and bright.
4.5.2 Materials. Verify the product does not require labeling as in 3.2.
4.5.3 Carcinogenicity and mutagenicity test.
4.5.3.1 Carcinogenicity test. A mouse skin bioassay shall be performed as specified in
Appendix requirements for mouse skin study. However, historical informations may be used in
lieu of this as indicated in contract or order (see 6.2 and 6.4).
4.5.3.2 Mutagenicity test. An invitro genotoxicity test shall be performed in accordance with
ASTM E 1687.
4.5.3.3 White oil purity test. The fog oil shall be tested to estimate the aromatic content. A
content and absorbance value in excess of 200 units at 280 to 290 nanometers shall be cause for
rejection. The test shall be conducted in accordance with FDA 21 CFR Part 3620-White Oil
Purity Test, Chapter 178, Subpart B. Laboratory shall state the dilution factor used in the test.
5