MIL-PRF-83282D
ASQC-Z1.4, Inspection Level S-3. The sample size and number of determinations shall be in
accordance with table IV.
TABLE IV. Sample for solid particle contamination.
Container
Sample size (ml) 1/
Number of determinations per sample
l quart
l00
l
l gallon
200
2
5 gallon
300
3
55 gallon
600
6
1/ Each determination shall be made on a 100 ml portion of the sample. If the particle count on any
individual determination exceed the limits of table III, two additional determinations on another sample
from the same container may be used. The container shall be thoroughly shaken immediately prior to
withdrawing each 100 ml portion for such determinations. The average of the two closer particle
counts shall be considered the particle count for the sample.
4.4 Tests. The hydraulic fluid properties shall be determined in accordance with table V and
4.4.1 through 4.4.4.2 Physical and chemical values specified in section 3 apply to the average of
the determinations made on the samples for those values which fall within any stated repeatability
or reproducibility limits of the applicable test method.
9