MIL-PRF-5606H
the viscosity decrease of the reference fluid (see 6.4.1), at 40°C is approximately 15
percent. Use 30 ml of fluid for this test.
4.4.3.4 Copper strip corrosion
The following procedures shall be followed:
a. Prepare two copper strips in accordance with ASTM D 130.
b. Fill test tubes or other suitable containers with 90 ml of hydraulic fluid and
individually immerse the copper strips into the test tubes.
c. Immerse each test tube, which will be equipped with an air condenser, in a
constant temperature bath capable of maintaining the fluid temperature at 135 +1°C. If
an oven is used, vent the air condenser to the outside of the oven. After 72 hours at this
test temperature, remove the strips from the fluid, rinse them in isooctane per
ASTM D 130, and compare the results with the ASTM copper strip corrosion standards.
4.4.3.5 Bulk modulus
The isothermal secant bulk modulus test shall be performed as specified in Appendix A.
4.4.4 Examination of filled containers
Each filled container and shipping container sample shall be examined for construction
defects of the container and closure, evidence of leakage, and net content. Any
container in the sample that has one or more defects, or is below the required fill, shall
be rejected. If the number of defective containers in any sample exceeds the
acceptance number for the appropriate sampling plan, the lot represented by the sample
shall be rejected. Rejected lots may be resubmitted for acceptance inspection provided
the contractor has removed or repaired all nonconforming containers.
5.
PACKAGING
5.1 Packaging
For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When actual packaging of materiel is to be performed by
DoD personnel, these personnel will contact the responsible packaging activity to
ascertain requisite packaging requirements. Packaging requirements are maintained by
the Inventory Control Point's packaging activity within the Military Department or
Defense Agency, or within the Military Department's Systems Command. Packaging
data retrieval is available from the managing Military Department or Defense Agency's
automated packaging files, CD-ROM products, or by contacting the responsible
packaging activity.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business