MIL-PRF-23699G
The post-test sludge content shall be determined as follows:
g. Decant oil from the test tube through a preweighed l0.0 micron
polytetrafluouroethylene filter (Militec LCWP 047-00 or equivalent) and measure
filtrate volume.
h. Set filtrate aside for viscosity and acid number tests.
i. Remove all sludge from test equipment with rubber policeman, wash equipment and
filtered sludge with petroleum ether, oven dry sludge sample, and weigh and compute
sludge weight per 100 mL of oil.
j. Do not add the petroleum ether washings to the oil filtrate used for viscosity and acid
number. Petroleum ether, with a boiling range of 30 to 60 °C, n-heptane, or hexane
shall be used in place of 1,1,1-trichloroethane (O-T-620).
4.4.13 Gear load carrying ability. The average of six determinations for STD, C/I, and HTS
classes of oil shall be not less than 102 percent of the reference oil (Hercolube A, see 4.4.13.1)
when tested in accordance with FED-STD-791, method 6508 and table II. The average of six
determinations for EE class of oil shall not be less than 110 percent of the reference oil. All six
determinations shall be made on the same machine. The reference oil average rating used to
obtain the relative ratings shall also be reported. Only the Ryder gear machines having a
reference oil average rating of 2,100-2,600 lb/in. after eight determinations are acceptable.
4.4.13.1 Source for standard reference oil for Ryder Gear Test (table II). Standard
reference oil may be obtained from the Naval Air Systems Command, AIR 4.4.2.2, Propulsion
Lubricants Team, 22229 Elmer Road, Building 2360, Unit 4, Patuxent River, MD 20670-1534.
4.4.14 Bearing deposits.
a. Post test oil viscosity sample is compared with viscosity of new oil samples tested at
40 °C. Post test oil total acid number is compared to the total acid number of the new oil
sample. The viscosity shall be determined in accordance with ASTM D445. The total
acid number shall be determined in accordance with SAE ARP5088.
4.4.14.1 Classes STD and C/I. The qualification sample will be evaluated in a 100 hour test
in accordance with table II (FED-STD-791, Method 3410, severity level 1-1/2).
4.4.14.2 Classes HTS and EE. The qualification sample will be evaluated in a 200 hour
test in accordance with table II (FED-STD-791, Method 3410, severity level 1-1/2).
4.4.15 Minisimulator test. The enhanced ester qualification sample after a 100-hour
minisimulator test (SAE ARP6166) shall perform in accordance with table II.
a. Post test oil viscosity sample is compared with viscosity of new oil samples tested at
40 °C. Post test oil total acid number is compared to the total acid number of the new
18
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business